Detectors, Testers & Meters
Page | 1 | 2 |

Current Catalog - pdf

Voltage Detector and Phasing Voltmeter
81280 (300V - 25KV) 83280 (300V - 35KV)

Dual application design for use as voltage detector or phasing voltmeter

Five-position switch controls different functions:

C - Indicates voltage on capacitive test points
CP - Phases using capacitive test points
L - Detects voltage on overhead and underground lines
LP - Phasing on overhead lines
BT - Battery Test

Completely shielded to minimize stray field interference
Easy to read analog meter scale
3kV test device to verify unit and accuracy
No extension resistors required
Optional adapters available for underground use up to 35kV
Connector cable protected with clear PVC covering
Watertight construction

Cat. No. Description
Weight
300 V - 25 KV
81280Q Quick Change
15 lbs (6.8 kg)
81280U Universal
15 lbs (6.8 kg)
81280GA Grip All
15 lbs (6.8 kg)
81280H6 Quick Change with Handles
25 lbs (11.3 kg)
300 V - 35 KV
83280Q Quick Change
15 lbs (6.8 kg)
83280U Universal
15 lbs (6.8 kg)
83280GA Grip All
15 lbs (6.8 kg)
83280H6 Quick Change with Handles
25 lbs (11.3 kg)
Cat. No. Description
Weight
300 V - 25 KV UNDERGROUND & OVERHEAD
81280QS Quick Change
21 lbs (9.5 kg)
81280US Universal
21 lbs (9.5 kg)
81280GAS Grip All
21 lbs (9.5 kg)
These sets come with 2 bushing adapters.
300 V - 35 KV UNDERGROUND & OVERHEAD
83280QS Quick Change
21 lbs (9.5 kg)
83280US Universal
21 lbs (9.5 kg)
83280GAS Grip All
21 lbs (9.5 kg)
These sets come with 2 bushing adapters.

Voltage Detector - VDA0300 / VDAH300 (0 - 300kV)

Widest voltage range (4kV - 500kV) available in one voltage detector. Designed for use on overhead and underground systems

Indicates approximate nominal or induced voltage in
line-to-ground values
Easy to read analog scale
Dual linear / logarithmic scale for better resolution on 4kV systems
Requires no voltage scale selector switch or multipliers
Hold and backlight functions available on VDAH300
Totally passive meter function
Optional adapters available for underground use up to 35kV
Watertight construction
Cat. No. Description
Weight
0 - 300 KV
VDA0300U Universal
18 Ibs (8.16 kg)
VDA0300GA Grip All
18 Ibs (8.16 kg)
VDA0300Q Quick Change
18 Ibs (8.16 kg)
VDA0300H6 Quick Change with Handles
18 Ibs (8.16 kg)
Cat. No. Description
Weight
0 - 300 KV
VDAH300U Universal with hold light feature
18 Ibs (8.16 kg)
VDAH300GA Grip All
18 Ibs (8.16 kg)
VDAH300Q Quick Change
18 Ibs (8.16 kg)
VDAH300H6 Quick Change with Handles
18 Ibs (8.16 kg)

Voltage Detector - VDA040P (0 - 40KV)

Dual application design. Detects voltage both as a proximity or direct contact meter on overhead and underground systems.

Cat. No. Description
Weight
0 - 40 KV
VDA040PU Universal
18 Ibs (8.16 kg)
VDA040PGA Grip All
18 Ibs (8.16 kg)
VDA040PQ Quick Change
18 Ibs (8.16 kg)
VDA040PH6 Quick Change with Handles

Five-position selector switch controls different functions:
 
P - Indicates voltage in proximity to line
URD - Detects voltage on underground systems
OH - Detects overhead voltage 0 - 10kV
X4 - Detects overhead voltage 11 - 40kV
T - Tests and verifies meter function
Selector switch calibrated for height above ground to compensate for capacitive coupling effect
Reads only contacted test point. Indicates line-to-ground values for nominal or induced voltages
Easy to read analog scale
Over load protected up to 66.5kV (115kV phase-to-phase)
Completely shielded to minimize stray field interference
Optional adapters available for underground use up to 35kV
Watertight construction

Voltage Detector - VDA040C (0 - 40KV)

Multi-function design for voltage detection on overhead and underground systems with ability to read capacitive test points.

Cat. No. Description
Weight
0 - 40 KV
VDA040CU Universal
18 Ibs (8.16 kg)
VDA040CGA Grip All
18 Ibs (8.16 kg)
VDA040CQ Quick Change
18 Ibs (8.16 kg)
VDA040CH6 Quick Change with Handles

Five-position selector switch controls different functions:
 
P - Indicates voltage in proximity to line
URD - Detects voltage on underground systems
OH - Detects overhead voltage 0 - 10kV
X4 - Detects overhead voltage 11 - 40kV
T - Tests and verifies meter function
Selector switch calibrated for height above ground to compensate for capacitive coupling effect
Reads only contacted test point and indicates line-to-ground values for nominal or induced voltages
Easy to read analog scale
Over load protected up to 66.5kV (115kV phase-to-phase)
Completely shielded to minimize stray field interference
Optional adapters available for underground use up to 35kV
Watertight construction

Digital Voltmeter - PD50 (0 - 50kV)

Designed for measuring voltage and phasing on overhead and underground systems

Cat. No. Description
Weight
0 - 50 KV
PD50U Universal
18 Ibs (8.16 kg)
PD50GA Grip All
18 Ibs (8.16 kg)
PD50Q Quick Change
18 Ibs (8.16 kg)

Can be used on capacitive test points to detect voltage
Completely shielded to minimize stray field interference
Easy to read LCD digital meter
Optional adapters available for underground use up to 35kV
No extension resistors required
Connector cable protected by clear PVC covering
3kV test device included to verify unit and accuracy
Watertight construction

RVD 50 High Line Resistive Digital Voltmeter (0 - 50kV)

Designed for reading AC voltages with an accuracy range of + or - 2%
0 - 50 KV

Cat. No. Description
Weight
0 - 50 KV
RVD50U Universal
18 Ibs (8.16 kg)
RVD50GA Grip All
18 Ibs (8.16 kg)
RVD50Q Quick Change
18 Ibs (8.16 kg)

Easy to read LCD digital meter
Completely shielded to minimize stray field interference
Connector cable protected by clear PVC covering
No extension resistors required
3kV test device included to verify unit and accuracy
Optional adapters available for underground use up to 35kV
Watertight construction

Phase Sequence Indicator

Cat. No. Description
Weight
84600 600 Volts at 25 - 60 Hz
2 lbs (0.91 kg)

Used to determine the proper sequence on all polyphase circuits prior to connecting phase sensitive loads such as pumps or motors. They will indicate the presence of all phases as well as phase sequencing. Case is included.

CAUTION: USE RUBBER GLOVES. DO NOT LEAVE CONNECTED LONGER THAN 1 MINUTE.

Page | 1 | 2 |