Insulated Probe

Cat. No.
Length
Weight
IP00036
36" (91.4 cm)
2 lbs (0.91 kg)
IP00048
48" (122.0 cm)
3 lbs (1.36 kg)

Used to help locate underground objects.

Ground Adapter Device Kit
Non-Load Break

Cat. No.
Weight
76174459
15 lbs (6.80 kg)

EACH SET INCLUDES THE FOLLOWING:

Cat. No. Description
Qty.
Weight
44C Ratchet Wrench with Ball and Ring
1
2 lbs (0.91 kg)
5900Q Universal Toggle and Spring
1
1 lb (0.45 kg)
5900CS Captured Socket with Friction Balls
1
8 oz (0.22 kg)

Cat. No. Description
Qty.
Weight
9206GAS Elbow Connector Tool with Inserts
1
2 1/2 lbs (1.13 kg)
1725001 Ground Stud
3
2 1/2 lbs (1.13 kg)
B1715 Protective Bag with Zipper
1
1lb (0.45kg.)

Enables application of personal grounds up to a 600 amp separable pre-molded component system when used with a “shotgun.”

Underground Grounding Studs

Cat. No. Description
Fault Duty
15 Cycles
Weight
1725 Underground Power Distribution Connectors, 3/4" Male
10 kA
1 1/2 lbs (0.68 kg)
1725F With 5/8" Female Thread
10 kA
1 1/2 lbs (0.68 kg)
1725001 With Copper Electrode and Socket Drive
17 kA
2 1/2 lbs (1.13 kg)
17250003 With 5/8"-11 Male Thread and Guide
27 kA
2 lbs (0.91 kg)
17250004 With 5/8"-11 Female Thread and Guide
27 kA
2 lbs (0.91 kg)
17250005 With 3/4"-10 Male Thread only
27 kA
2 lbs (0.91 kg)

The 172 grounding stud for 600 amp systems is a 10" (25.4 cm) long T-bar with a 3/4"-10 thread to screw into
the spade terminal. Protective yellow cap keeps dirt out of the connector. After a cable has been proven de-energized, the stud is installed and a ground is applied to the cross bar.

The 1725001 (A) grounding stud is made of copper with a thread on one end and a 1" (2.5 cm) hex drive on the
other end. Fitted with a tapered guide and two perpendicular grounding jumper perches used to install the ground. A socket drive is used for the installation. For application, use Cat. No. 5900CS captured socket.

The 17250003 (B), 17250004 (C) and 17250005 (D) grounding studs and plugs come with highly visible yellow
plug covers designed to help keep out debris during operation. Supplied with “shotgun” tool connectors. Designed with sturdy lip to ensure clamp contact during faults. Used for grounding equipment such as nonload-break connectors or power distribution connectors.


OPTIONAL PARTS
Cat. No. Description
Weight
5900CS Captured Socket for 1725001 or 600 Amp Plug
8 oz (0.22 kg)
3402Q Convertible Adapter, Grip All to Quick Change
3 oz (0.09 kg)
3402U Convertible Adapter, Grip All to Universal
3 oz (0.09 kg)

200 Amp Grounded Bushing Sets

The single bushing ground set is a single lead made from 6 feet (1.83 m) of 1/0 cable. The cluster bushing set consists of 3 bushing assemblies connected together with 3-foot (0.92 m) leads to a common connection, and 10 feet (3.05 m) from common connection to ground. The conductor is made of 1/0 clear jacketed copper stranded cable. The ground clamp (Cat. No. 7640001) can be applied with a “shotgun.” Clusters come complete with bag (Cat. No. B766); single leads do not. All sets meet ASTM F-855 Grade 2 specifications. Other lengths and configurations are available.


DEAD BREAK
Cat. No. Description
Weight
EB100615 Single, 15 kV
8 lbs (3.63 kg)
EB1021015 Cluster, 15 kV
20 lbs (9.30 kg)

LOAD BREAK
Cat. No. Description
Weight
EB100615LB Single, 15 kV
9 lbs (4.08 kg)
EB1021015LB Cluster, 15 kV
22 lbs (9.98 kg)
EB100625LB Single, 25 kV
10 lbs (4.53 kg)
EB1021025LB Cluster, 25 kV
23 lbs (10.43 kg)

200 Amp Ground Bushings with Connections

DEAD BREAK
Cat. No. Description
Weight
764015SO Single, 15 kV
1 lb (0.45 kg)

LOAD BREAK
Cat. No. Description
Weight
764150015LSO Single, 15 kV
2 lbs (0.91 kg)
764150025LSO Cluster, 25 kV
4 lbs (1.81 kg)

Ground bushings (parking stands for ‘J’ boxes or padmounts) provide a safe, convenient ground for elbows and a “positive” test to ensure a de-energized elbow.

200 Amp Elbow Grounding Sets

A single lead made from 6 feet (1.83 m) of 1/0 cable. Consists of 3 elbow assemblies connected together with 3-foot (0.92 m) leads to a common connection, and 10 feet (3.05 m) from common connection to ground. The conductor is made of 1/0 clear jacketed copper stranded cable. Ground clamp (Cat. No. 7640001) can be applied with a “shotgun.” Sets are rated for a maximum fault current of 10,000 amps for 17 cycles. Clusters come complete with bag (Cat. No. B766); single leads do not. Other lengths and configurations are available.


DEAD BREAK
Cat. No. Description
Weight
ES100615 Single, 15 kV
8 lbs (3.63 kg)
ES1021015 Cluster, 15 kV
20 lbs (9.30 kg)

LOAD BREAK
Cat. No. Description
Weight
ES100615LB Single, 15 kV
9 lbs (4.08 kg)
ES1021015LB Cluster, 15 kV
22 lbs (9.98 kg)
ES100625LB Single, 25/35 kV
10 lbs (4.53 kg)
ES1021025LB Cluster, 25/35 kV
23 lbs (10.43 kg)


200 Amp Ground Elbow with Connections

DEAD BREAK
Cat. No. Description
Weight
764015GE 15 kV
1 lb (0.45 kg)

LOAD BREAK
Cat. No. Description
Weight
764150015LGE 15 kV
1 lb (0.45 kg)
764150025LGE 25/35 kV
2 lbs (0.91 kg)

May be used on single phase or three phase installations. Grounding sets come complete with extra flexible cable and connections. Elbows are rated for a maximum fault current of 10,000 amps for 17 cycles. All the clamps come with grip all eyes for use with “shotguns.”

200 Amp Elbow Connector Tool

Cat. No. Description
Weight
9202Q Quick Change Fitting
2 lbs (0.91 kg)
9202U Universal Fitting
2 lbs (0.91 kg)
9202GA Grip-All Fitting
2 lbs (0.91 kg)

Designed to fit all the 15kV and 25 kV rated loadbreak and non-loadbreak elbows. The jaws are contoured to provide a positive grip and not interfere with the contact interface area, allowing the elbow to operate properly while connecting or disconnecting.

600 Amp Elbow Connector Tool

Cat. No. Description
Weight
9206Q Quick Change
2 lbs (0.91 kg)
9206U Universal
2 lbs (0.91 kg)
9206GA Grip-All
2 lbs (0.91 kg)
9206GAS With Insert Pair for 200 AMP Elbows
2 lbs (0.91 kg)
9202I Insert Pair
8 oz (0.22 kg)

Designed to fit the basic shielded elbow. Adjustable for operating with the large size conductors assembled in the elbow. The jaws can be set to operate vertically or set to operate at a 30° or 45° angle. Inside diameter is 35/8" (9.2 cm). The insert is a special configuration allowing the elbow connector tool to be used on smaller size elbows.

Insulated Elbow Remover

Cat. No. Description
Weight
9204HIP 4' (1.22 m) with Cat. No. 9202HQ
10 lbs (4.53 kg)
9206HIP 6' (1.83 m) with Cat. No. 9202HQ
11 lbs (4.99 kg)
9208HIP 8' (2.44 m) with Cat. No. 9202HQ
12 lbs (5.44 kg)

PARTS
Cat. No. Description
Weight
9202HQ Elbow Remover Head with Quick Change
2 lbs (0.91 kg)
9202HPQ Impact Hammer with Quick Change
6 lbs (2.72 kg)
12524HH Insulated Stick for 4' (1.22 m) Remover

2 lbs (0.91 kg)
12548HH Insulated Stick for 6' (1.83 m) Remover
3 lbs (1.36 kg)
12572HH Insulated Stick for 8' (2.44 m) Remover
4 lbs (1.81 kg)

The insulated elbow remover is used by inserting a hook in the loop on the back of any elbow while applying a hammering action. This tool can also be used to seal elbows when installing them. Other lengths available.


Concentric Neutral Jumper Assembly

Cat. No. Description
For Cable Diameter
Weight
7603 Assembly
3/4" to 2" (1.9 - 5.1 cm)
12 lbs (5.44 kg)
7603GA Grip All Assembly
3/4" to 2" (1.9 - 5.1 cm)
12 lbs (5.44 kg)
7604 Assembly
2" to 4" (5.1 - 10.2 cm)
12 lbs (5.44 kg)
7604GA Grip All Assembly
2" to 4" (5.1 - 10.2 cm)
12 lbs (5.44 kg)

PARTS
Cat. No. Description
Weight
7603C Clamp with Wing Nut
4 lbs (1.81 kg)
7603CGA Clamp with Grip All
4 lbs (1.81 kg)
7604C Clamp with Wing Nut
4 lbs (1.81 kg)
7604CGA Clamp with Grip All
4 lbs (1.81 kg)

BAG
Cat. No. Description
Weight
B1715 Protective Bag
1 lb (0.45 kg)


Used for bonding purposes on non-jacketed cable. It is usually installed across a portion of cable to be cut, repaired, or spliced. The assembly is left in place until the concentric neutral is spliced. As a safety precaution, follow all of your organization’s applicable rules and/or policies pertaining to faulted cable, spiking, and grounding.

Made with two ground clamps and 4 feet (1.22 m) of 1/0 clear jacketed extra flexible copper cable. The concentric neutral ground clamp is spring pressured. The assemblies have a fault duty of 17 kA and meet ASTM F-855 grade 2 specifications. Other lengths are available. Bag not included.

15 KA Underground Dead Break Ground Set

LOCAL LOOP
Cat. No. Description
Weight
764156STGESO Full Assembly with Bag
21 lbs (9.52 kg)

The URD deadbreak components provide safe and simple grounding methods on padmount transformers or any related URD equipment. These grounds can be ordered in complete sets or individual components. The jumpers are made with 6 foot
(1.83 m) lengths of #2, clear-jacketed, extra flexible cable. Clamps (Cat. No. 7640001C) supplied include an eye for a gripall insulating stick application.

ASSEMBLY INCLUDES:
Cat. No.
Qty.
Description
Weight
764156234H
3
Ground Jumper, 6' (1.83 m)
6 lbs (2.72 kg)
764000ST
3
Ground Stud for Low Profile Transformer
1 lb (0.45 kg)
764015GE
3
15 kV Ground Elbow
1 lb (0.45 kg)
764015S0
3
15 kV Ground Standoff with Spring Bail
1 lb (0.45 kg)
B1715
1
Protective Bag
2 lbs (0.91 kg)